The DAB Mascontrol Pump Controller Replaces the Tank and the Switch
A pressure tank stores water so the pump does not restart every time someone opens a valve. This does the same job electronically, in a head that threads onto the discharge side. Mas Control watches pressure and flow together, not just pressure. It starts the pump when pressure drops to 31.9 psi and stops it a few seconds after flow ceases. Bypass flow above 0.21 gpm is enough to hold it running. This is the 1 in NPT male version, rated for flows up to 15 gpm and 145 psi maximum working pressure. It will switch a motor drawing up to 16 FLA at 115V or 20 FLA at 230V. Liquid up to 149°F is within spec. Run-dry protection cuts the motor when the suction line loses water. A restart button brings it back once the cause is fixed.
Mounting an Electronic Pump Controller on a Vertical Column
Mount it on a vertical water column with the electronics box level. That is a requirement, not a preference. Laid on its side the internal valve will not seat properly, and you get nuisance cycling or a controller that never releases the pump. The body is PA6GF30 reinforced polyamide with an AISI 304 stainless flow valve, an EPDM diaphragm and a stabilized steel spring. Electronics sit behind a NEMA 12 enclosure with a half-inch NPT conduit entry, so it wires like any other piece of pump-room gear. Two limits decide whether this is the right controller for a given system. The flow ceiling above is the first, and a pump that regularly moves more than that needs the 1-1/4 in version instead. The second limit is cycling. On a line with small persistent leaks the pump restarts on every drip, where a pressure tank would have absorbed them. A small buffer tank alongside the controller fixes that without giving up constant pressure.
Key Features
- 31.9 psi Cut-In: Starts the pump as soon as pressure falls to the setpoint, so taps and emitters see steady delivery.
- Pressure and Flow Sensing: Reads both, which is why it stops on no-flow rather than waiting for pressure to climb.
- Run-Dry Protection: Cuts the motor when the suction line loses prime, before the mechanical seal overheats.
- 1 in NPT Male Connections: Threads straight onto a vertical riser off the pump discharge with no adapters.
- 115V/230V Dual Voltage: Switches up to 16 FLA at 115V or 20 FLA at 230V, covering most single-phase jet and booster pumps.
- NEMA 12 Enclosure: PA6GF30 body, AISI 304 valve and EPDM diaphragm hold up in humid, splash-prone pump rooms.
Technical Specifications
| Specification | Value |
|---|---|
| Model | MASCONTROL MC/USA 1 |
| Cut-In Pressure | 31.9 psi |
| Maximum Working Pressure | 145 psi |
| Maximum Flow | 15 gpm (1 in version) |
| Minimum Bypass Flow | 0.21 gpm |
| Power Supply | 115V / 230V, 50/60 Hz |
| Current Rating | 16 FLA at 115V / 20 FLA at 230V |
| Water Connections | 1 in NPT male, inlet and outlet |
| Conduit Entry | 0.5 in NPT |
| Maximum Liquid Temperature | 149°F (65°C) |
| Mounting | Vertical water column, electronics box level |
| Enclosure | NEMA 12 |
| Body Material | PA6GF30 reinforced polyamide |
| Flow Valve / Diaphragm / Spring | AISI 304 stainless / EPDM / stabilized steel |
| Dry-Run Protection | Yes, with manual restart button |
| Weight | 3.5 lb (1.6 kg) |